FFD110-12 Dual Purpose AGM Battery

Previous 9 / 15 Next

FFD110-12 Dual Purpose AGM Battery Marine Application Fullriver AGM Battery FFD110-12 Dual Purpose AGM Battery Marine Application Fullriver AGM Battery FFD110-12 Dual Purpose AGM Battery Marine Application Fullriver AGM Battery FFD110-12 Dual Purpose AGM Battery Marine Application Fullriver AGM Battery FFD110-12 Dual Purpose AGM Battery Marine Application Fullriver AGM Battery FFD110-12 Dual Purpose AGM Battery Marine Application Fullriver AGM Battery FFD110-12 Dual Purpose AGM Battery Marine Application Fullriver AGM Battery FFD110-12 Dual Purpose AGM Battery Marine Application Fullriver AGM Battery


Download Files

FFD110-12.pdf (321.08 KB)
dc-Installation_Manual.pdf (1.58 MB)
dc-Charging_Instructions.pdf (1.04 MB)
Cycling Capacity
20 hour rate: 110 Amp Hours
Reserve Capacity
@ 25 Amps: 205 minutes
@ 75 Amps: 50 minutes
Mechanical Specifications
Group Size: 31
Terminal Type: M8 (w/ TP08 Brass AP Included)
Total Height: 9.49″ (241 mm)
Height: 8.43″ (214 mm)
Width: 6.77″ (172 mm)
Length: 12.91″ (328 mm)
Weight: 66.1 lbs (30 kg)
Case Type: ABS Plastic – Flame Res Rating UL94-HB
Electrical Specifications
Nominal Voltage: 12 Volt
Capacity @ 100 hour rate: 115 AH
Capacity @ 20 hour rate: 110 AH
Capacity @ 10 hour rate: 90 AH
Capacity @ 5 hour rate: 82 AH
CCA: 850 Amps
CA or MCA: 1050 Amps
PHCA: 1600 Amps
Short Circuit Current: 2650 Amps
Internal Resistance: 9m Ω

Discharge Table (Constant Current)

Time Amps Rate
20 hr 5 0.05 CA
10 hr 9 0.1 CA
8 hr 10.6 0.13 CA
5 hr 16.4 0.25 CA
3 hr 28 0.33 CA
2 hr 32.5 0.5 CA
1 hr 60.6 1 CA

Charge Voltages

Charge Stage Battery Voltages-12V Battery Voltages-24V Battery Voltages-36V Battery Voltages-48V
Bulk 14.7 V 29.4 V 44.1 V 58.8 V
Absortion 14.7 V 29.4 V 44.1 V 58.8 V
Float 13.6 V 27.2 V 40.8 V 54.6 V
TC Factor: -4mV/°C/cell

Temperature Range Specifications

Condition Recommended Maximum
Storage -15°C to 50°C -40°C to 71°C
Operation -15°C to 40°C -40°C to 71°C
Charge with TC -15°C to 50°C -40°C to 71°C
Charge without TC 0°C to 40°C -15°C to 50°C

Terminal Torque Specifications

Terminal Type ft-lbs in-lbs Nm
AP | DT (AP) | M6 | M6M (stud) | TP07 (AP) | TP08 (AP) 4.2 – 6.0 50 – 70 5.6 – 7.9
FR45 6.0 – 7.5 70 – 90 7.9 – 10.1
M8 7.1 – 8.0 85 – 95 9.6 – 10.7
DT (stud) | M10M (stud) 9.2 – 10.4 110 – 125 12.2 – 14.0