FFD80-12 Dual Purpose AGM Battery

Previous 8 / 8 Next

FFD80-12 Dual Purpose AGM Battery Material Handling Application Fullriver AGM Battery FFD80-12 Dual Purpose AGM Battery Material Handling Application Fullriver AGM Battery FFD80-12 Dual Purpose AGM Battery Material Handling Application Fullriver AGM Battery FFD80-12 Dual Purpose AGM Battery Material Handling Application Fullriver AGM Battery FFD80-12 Dual Purpose AGM Battery Material Handling Application Fullriver AGM Battery FFD80-12 Dual Purpose AGM Battery Material Handling Application Fullriver AGM Battery FFD80-12 Dual Purpose AGM Battery Material Handling Application Fullriver AGM Battery FFD80-12 Dual Purpose AGM Battery Material Handling Application Fullriver AGM Battery


Download Files

FFD80-12.pdf (303.65 KB)
dc-series-12.pdf (318.94 KB)
dc-Installation_Manual.pdf (1.58 MB)
dc-Charging_Instructions.pdf (1.04 MB)
Cycling Capacity
20 hour rate: 80 Amp Hours
Reserve Capacity
@ 25 Amps: 150 minutes
@ 75 Amps: 35 minutes
Mechanical Specifications
Group Size: 24
Terminal Type: M6
Total Height: 8.46″ (215 mm)
Height: 8.31″ (211 mm)
Width: 6.65″ (169 mm)
Length: 10.24″ (260 mm)
Weight: 50.9 lbs (23.1 kg)
Case Type: ABS Plastic – Flame Res Rating UL94-HB
Electrical Specifications
Nominal Voltage: 12 Volt
Capacity @ 100 hour rate: 88 AH
Capacity @ 20 hour rate: 80 AH
Capacity @ 10 hour rate: 68 AH
Capacity @ 5 hour rate: 56 AH
CCA: 530 Amps
CA or MCA: 650 Amps
PHCA: 1200 Amps
Short Circuit Current: 1540 Amps
Internal Resistance: 9m Ω

Discharge Table (Constant Current)

Time Amps Rate
20 hr 4 0.05 CA
10 hr 6.8 0.1 CA
8 hr 8.2 0.13 CA
5 hr 11.2 0.25 CA
3 hr 17.1 0.33 CA
2 hr 22.8 0.5 CA
1 hr 40.6 1 CA

Charge Voltages

Charge Stage Battery Voltages-12V Battery Voltages-24V Battery Voltages-36V Battery Voltages-48V
Bulk 14.7 V 29.4 V 44.1 V 58.8 V
Absortion 14.7 V 29.4 V 44.1 V 58.8 V
Float 13.6 V 27.2 V 40.8 V 54.6 V
TC Factor: -4mV/°C/cell

Temperature Range Specifications

Condition Recommended Maximum
Storage -15°C to 50°C -40°C to 71°C
Operation -15°C to 40°C -40°C to 71°C
Charge with TC -15°C to 50°C -40°C to 71°C
Charge without TC 0°C to 40°C -15°C to 50°C

Terminal Torque Specifications

Terminal Type ft-lbs in-lbs Nm
AP | DT (AP) | M6 | M6M (stud) | TP07 (AP) | TP08 (AP) 4.2 – 6.0 50 – 70 5.6 – 7.9
FR45 6.0 – 7.5 70 – 90 7.9 – 10.1
M8 7.1 – 8.0 85 – 95 9.6 – 10.7
DT (stud) | M10M (stud) 9.2 – 10.4 110 – 125 12.2 – 14.0

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

Get In Touch
Switch to Mobile Version
Recent Updates